Search in Category
Filter Paper
Search term required.
Filter Your Search
Grade
Material
Name
Pore Size
Size
Sterility
Type
Browse Categories
Loading...
Filter Paper
Viewing Page 26 of 33
(321 results)
Filter Paper Qualitative 7.0cm 100pk
Item #:
ETD/6310-0700
Supplier #: 6310-0700
Supplier #: 6310-0700
FILTER PAPER Qualitative High Purity Grade 631 7 cm circle 100/pk Exact Match 47749-690
Filters Grade A/E 90mm PK/100
Item #:
TMS/1229B38
Supplier #: 1229B38
Supplier #: 1229B38
Depth filtration glass micro fiber GRADE A-E - Fine porosity and fast flow rate, with a 1.0 µm size particle retention. Binderless borosilicate glass microfiber. DOP efficiency is 99.98%. Primarily used in suspended solids and air monitoring. Particle retention: 1.00 µm Filtration speed: 15 seconds Thickness: 0.33 mm Basis weight: 60 g/m 2 Depth filtration categorizes filter media that traps particulate within the random matrix of fibers found within the thickness of the media. The efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence of, if any, binder material that acts as a strengthening agent and aids in holding the fibers together. Because of the characteristically high flow rates of depth filters, they are generally used in applications such as single and multi-process removal of sediment and course particulate. Glass micro fiber filters are available without binders, making the inertmatrix an ideal medium to entra-sediment for further analysis and counting. Also, depth filtration media is commonly used as pre-filtration prior to surface filtration substrates such as membranes.
Bottle-Top Filters, 45 mm, 500 ml
Item #:
TMS/1234K63
Supplier #: 1234K63
Supplier #: 1234K63
NALGE NUNC INTERNATIONAL
Mfg Item # : 595-4520
Nalgene filters have the Rapid-Flow multi-column membrane-support system. This proprietary system provides a uniform, consistent separation between touchpoints with the membrane, minimizing gap stress to maintain optimal flow. Polystyrene housing 90mm Supor®* machV PES membrane 90-mm diameter membranes for faster flow rates. Filters securely screw onto glass media bottles with 33- or 45-mm neck sizes. Allow direct flitration of liquid into sterile glass media bottles*. BLUE collar. Side-arm with quick-disconnect tubing adapter. Nalgene PES: The best choice for cell culture Polyethersulfone (PES) is the ultimate tissue culture membrane. It’s fast and clean. PES is low protein binding, so there is less chance of removing critical protein from your media. It is hydrophilic, so no external wetting agents or surfactants are needed, resulting in low extractables. And it is fast, so you spend less time waiting. WARNING! All NALGENE Filterware is for research use only, not for in vitro diagnosis or parenterals. *CAUTION: Use only sterile bottles designed for use with vacuum. Always use safety shield during vacuum procedures.
Mfg Item # : 595-4520
Nalgene filters have the Rapid-Flow multi-column membrane-support system. This proprietary system provides a uniform, consistent separation between touchpoints with the membrane, minimizing gap stress to maintain optimal flow. Polystyrene housing 90mm Supor®* machV PES membrane 90-mm diameter membranes for faster flow rates. Filters securely screw onto glass media bottles with 33- or 45-mm neck sizes. Allow direct flitration of liquid into sterile glass media bottles*. BLUE collar. Side-arm with quick-disconnect tubing adapter. Nalgene PES: The best choice for cell culture Polyethersulfone (PES) is the ultimate tissue culture membrane. It’s fast and clean. PES is low protein binding, so there is less chance of removing critical protein from your media. It is hydrophilic, so no external wetting agents or surfactants are needed, resulting in low extractables. And it is fast, so you spend less time waiting. WARNING! All NALGENE Filterware is for research use only, not for in vitro diagnosis or parenterals. *CAUTION: Use only sterile bottles designed for use with vacuum. Always use safety shield during vacuum procedures.
Glass Fiber Filter 0.7um 47mm pack/100
Item #:
TMS/4749A72
Supplier #: 4749A72
Supplier #: 4749A72
GVS Filter Technology Part No. 1215540
Extend the life of final filters Pore sizes from 0.5 µm to 1.0 µm With or without binders Autoclavable PreSep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Frequency and cost of replacing the final membrane filters is reduced. Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. Maximum operating temperature is 165°C (325°F). Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Not recommended for temperatures exceeding 510°C (950°F). For upstream protection of a membrane within a filter holder, the use of a prefilter that is slightly smaller in diameter than the main filter allows the prefilter to fit inside the O-ring or filter funnel holder seal, ensuring a positive membrane seal. When used as the main filter medium, select a diameter of the same size as the filter holder to be used. Type G15 Glass Fiber Prefilters with Binders (4749A02 to A14) Nominal pore size- 0.5 µm High rentention efficiency Limited dirt-handling capacity Protection of 0.2 µm to 0.8 µm final filters Type G20 Glass Fiber Prefilters with Binders (4749A20 to A32) Nominal pore size- 1.0 µm Surface capture of particles Average retention efficiency Higher dirt-handling capacity Protection of 0.8 µm and larger pore size final filters Type G25 Glass Fiber Prefilters with Binders (4749A40 to A54) Nominal pore size- 1.0 µm Thickness approximately 3.5 times greater than G20 Depth particle capture Average retention efficiency Highest dirt-handling capacity Recommended for solutions with heavy contaminate loads Protection of 0.8 µm and larger pore size final filters Type G40 Glass Fiber Prefilters WITHOUT Binders (4638D60 to D68) Nominal pore size- 1.0 µm Average retention efficiency Highest dirt-handling capacity Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents TCLP Glass Fiber Filters WITHOUT Binders, 0.7 µm Pore Size (4749A72) Borosilicate glass fiber filters designed for use in U.S. EPA Method 1311 Toxicity Characteristic Leaching Procedure (TCLP). Federal regulations require the filters for this application be made of borosilicate glass fiber, contain no binder materials and have an effective pore size of 0.6 to 0.8 microns. GE TCLP glass fiber filters have a pore size of 0.7 microns and are binder free. They are used in Zero-Headspace Extractor Vessels for determining the mobility of semi-volatiles. Filters should be acid washed prior to use with 1N nitric acid followed by three consecutive rinses with deionized water. A minimum of 1 liter per rinse is recommended.
Extend the life of final filters Pore sizes from 0.5 µm to 1.0 µm With or without binders Autoclavable PreSep prefilters are biologically inert and highly resistant to oxidizing agents and weak acids. Primarily used to extend the life of a final filter, they can also be used as a low-cost sample clarifier. Prefilters increase the speed of filtration by trapping large particles before they reach the final membrane filter. Frequency and cost of replacing the final membrane filters is reduced. Filters with binders are composed of borosilicate glass fibers woven into a porous matrix and bonded by an acrylic resin. The resulting filter reduces media migration and has the strength required for high-volume aqueous filtrations. Maximum operating temperature is 165°C (325°F). Glass prefilters without binders are designed to avoid binder extractables during solvent filtration or gravimetric analysis. Not recommended for temperatures exceeding 510°C (950°F). For upstream protection of a membrane within a filter holder, the use of a prefilter that is slightly smaller in diameter than the main filter allows the prefilter to fit inside the O-ring or filter funnel holder seal, ensuring a positive membrane seal. When used as the main filter medium, select a diameter of the same size as the filter holder to be used. Type G15 Glass Fiber Prefilters with Binders (4749A02 to A14) Nominal pore size- 0.5 µm High rentention efficiency Limited dirt-handling capacity Protection of 0.2 µm to 0.8 µm final filters Type G20 Glass Fiber Prefilters with Binders (4749A20 to A32) Nominal pore size- 1.0 µm Surface capture of particles Average retention efficiency Higher dirt-handling capacity Protection of 0.8 µm and larger pore size final filters Type G25 Glass Fiber Prefilters with Binders (4749A40 to A54) Nominal pore size- 1.0 µm Thickness approximately 3.5 times greater than G20 Depth particle capture Average retention efficiency Highest dirt-handling capacity Recommended for solutions with heavy contaminate loads Protection of 0.8 µm and larger pore size final filters Type G40 Glass Fiber Prefilters WITHOUT Binders (4638D60 to D68) Nominal pore size- 1.0 µm Average retention efficiency Highest dirt-handling capacity Recommended for solvent filtration, gravimetric analysis, contamination analysis of wastewater and industrial effluents TCLP Glass Fiber Filters WITHOUT Binders, 0.7 µm Pore Size (4749A72) Borosilicate glass fiber filters designed for use in U.S. EPA Method 1311 Toxicity Characteristic Leaching Procedure (TCLP). Federal regulations require the filters for this application be made of borosilicate glass fiber, contain no binder materials and have an effective pore size of 0.6 to 0.8 microns. GE TCLP glass fiber filters have a pore size of 0.7 microns and are binder free. They are used in Zero-Headspace Extractor Vessels for determining the mobility of semi-volatiles. Filters should be acid washed prior to use with 1N nitric acid followed by three consecutive rinses with deionized water. A minimum of 1 liter per rinse is recommended.
Nylaflo® Membrane Filter, 0.2 µm, 25mm
Item #:
VAN/28140-028
Supplier #: 28140-028
Supplier #: 28140-028
Pall Laboratory
Mfg Item # : 66601
Nylaflo* Membrane Disc Filter 0.2um pore. 25mm diameter. Hydrophilic nylon filter compatible with esters, bases, alcohols. Not for acids 1N or halogenated solvents. Naturally wettable to aqueous solutions. HPLC certified for low levels of UV-absorbing extractables. 100/pk.
Exact Match: 28140-028
Mfg Item # : 66601
Nylaflo* Membrane Disc Filter 0.2um pore. 25mm diameter. Hydrophilic nylon filter compatible with esters, bases, alcohols. Not for acids
Exact Match: 28140-028
Acrodisc Filters 0.45um 25mm
Item #:
VAN/28144-584
Supplier #: 28144-584
Supplier #: 28144-584
Pall Laboratory
Mfg Item # : 4501
Acrodisc* Syringe Filter, 25mm 0.45um. Hydrophobic PTFE membrane for exceptional chemical and temperature compatibility. HPLC certified for low level UV-absorbing extractables. Polypropylene housing. Female Luer-Lok* inlet, standard male slip Luer outlet. 100uL hold-up volume. 1000/pk.
Exact Match: 28144-584
Mfg Item # : 4501
Acrodisc* Syringe Filter, 25mm 0.45um. Hydrophobic PTFE membrane for exceptional chemical and temperature compatibility. HPLC certified for low level UV-absorbing extractables. Polypropylene housing. Female Luer-Lok* inlet, standard male slip Luer outlet.
Exact Match: 28144-584
Filter SUPR800 .8um 47mm pk/100
Item #:
VAN/28147-468
Supplier #: 28147-468
Supplier #: 28147-468
Pall Laboratory
Mfg Item # : 60110
Supor* Membrane Disc Filter 0.8um pore size. 47mm diameter. Plain, nonsterile. Supor hydrophilic polyethersulfone membrane for high flow rate, low protein binding, low extractables. Stronger than acetate and nitrate membranes. Very high water flow, fluid filtration capacity. Autoclavable. 100/pk.
Exact Match: 28147-468
Mfg Item # : 60110
Supor* Membrane Disc Filter 0.8um pore size. 47mm diameter. Plain, nonsterile. Supor hydrophilic polyethersulfone membrane for high flow rate, low protein binding, low extractables. Stronger than acetate and nitrate membranes. Very high water flow, fluid filtration capacity. Autoclavable. 100/pk.
Exact Match: 28147-468
Glass Fiber Filter 1.0um 25mm pk/1000
Item #:
VAN/34181-092
Supplier #: 34181-092
Supplier #: 34181-092
Pall Laboratory
Mfg Item # : 4529
Glass Fiber Membrane Filter 25mm diameter. 2.8cm2 filtration area. Prefilters aqueous and solvent based samples. 100% binder-free borosilicate glass fiber filter. Low extractables. Polypropylene housing. Female Luer-Lok* inlet. Male slip Luer outlet. 1.0um nominal pore size. 1000/pk.
Exact Match: 34181-092
Mfg Item # : 4529
Glass Fiber Membrane Filter 25mm diameter. 2.8cm2 filtration area. Prefilters aqueous and solvent based samples. 100% binder-free borosilicate glass fiber filter. Low extractables. Polypropylene housing. Female Luer-Lok* inlet. Male slip Luer outlet. 1.0um nominal pore size. 1000/pk.
Exact Match: 34181-092
Replacement Filter .45um Pack/10
Item #:
VAN/37001-878
Supplier #: 37001-878
Supplier #: 37001-878
INTEGRA BIOSCIENCE
Mfg Item # : 155499
Filter Nonsterile. Replacement 0.45um filter for all PIPETBOY acu* Pipet Controllers.
Exact Match: 37001-878
Mfg Item # : 155499
Filter Nonsterile. Replacement 0.45um filter for all PIPETBOY acu* Pipet Controllers.
Exact Match: 37001-878
FIlter Paper, Grd 315, 12.5cm dia,100/pk
Item #:
VAN/28331-026
Supplier #: 28331-026
Supplier #: 28331-026
VWR International 28331-026
VWR* Grade 315, Crepe Fluted Circles, Folded, Qualitative 12.5cm diameter. Ideal for gelatinous and coarse precipitates. Coarse porosity. Fast flow rate. 25um particle retention.
VWR* Grade 315, Crepe Fluted Circles, Folded, Qualitative 12.5cm diameter. Ideal for gelatinous and coarse precipitates. Coarse porosity. Fast flow rate. 25um particle retention.