Browse Categories

Electrode

Viewing Page 12 of 18 (180 results)
Conductivity Standard, 10,000µmho/cm 1L

Conductivity Standard, 10,000µmho/cm 1L

Item #: LCH/LC187772
Supplier #: LC187772

Conductivity Standard, 10,000µmho/cm 1L CAS#7447-40-7
UOM : EA


Add to Quote
Conductivity Standard, 12,856µmho/cm 1L

Conductivity Standard, 12,856µmho/cm 1L

Item #: LCH/LC187792
Supplier #: LC187792

Conductivity Standard, 12,856µmho/cm 1L CAS#7447-40-7
UOM : EA


Add to Quote
Conductivity Standard, 1409µmho/cm 10L

Conductivity Standard, 1409µmho/cm 10L

Item #: LCH/LC187806
Supplier #: LC187806

Conductivity Standard, 1409µmho/cm 10L CAS#7447-40-7
UOM : EA


Add to Quote
Conductivity Standard,1500µmho/cm 500mL

Conductivity Standard,1500µmho/cm 500mL

Item #: LCH/LC187861
Supplier #: LC187861

Conductivity Standard, 1500µmho/cm 500mL CAS#7447-40-7
UOM : EA


Add to Quote
Conductivity Standard, 8974µmho/cm 500mL

Conductivity Standard, 8974µmho/cm 500mL

Item #: LCH/LC187871
Supplier #: LC187871

Conductivity Standard, 8974µmho/cm 500mL CAS#7447-40-7
UOM : EA


Add to Quote
ConductivityStandard,15,000µmho/cm 500mL

ConductivityStandard,15,000µmho/cm 500mL

Item #: LCH/LC187891
Supplier #: LC187891

Conductivity Standard, 15,000µmho/cm 500mL CAS#7447-40-7
UOM : EA


Add to Quote
Conductivity Standard, 100,000µmho/cm 1L

Conductivity Standard, 100,000µmho/cm 1L

Item #: LCH/LC187912
Supplier #: LC187912

Conductivity Standard, 100,000µmho/cm 1L CAS#7447-40-7
UOM : EA


Add to Quote
Electrode pH Combination AG/AGCL

Electrode pH Combination AG/AGCL

Item #: VAN/10010-796
Supplier #: 10010-796

THERMO ORION 9165BNWP
Orion Sure-Flow* pH Electrode Orion epoxy body sure-flow* electrode with an ag/agcl internal reference system. Waterproof BNC connector with a one meter cable. Exact Match: 10010-796
UOM : EA


Add to Quote
General Combination Electrode, BNC

General Combination Electrode, BNC

Item #: TMS/4136L21
Supplier #: 4136L21

OI Analytical
Mfg Item # : 476086
General Purpose pH Combination (4136L21) AgCl internal reference sealed by ion exchange barrier pH range 0-14 at temperatures from 0° to 100°C Replaceable junction Plastic body 13 mm diameter x 138 mm long. 4136L16 and L21 have removable bulb connector for easy cleaning; also usable with solutions containing suspended solids and non-aqueous solutions. Replacement Junctions (4136L60) Furnished immersed in KCl solution in screw cap bottle Flat Surface pH Combination (4136L96) AgCl internal reference sealed by ion exchange barrier Flat surface with Corning junction, which can be pulled out and replaced if it becomes fouled Usable with solutions of high viscosity and semi-solid substances. pH range 0-14 at temperatures from 0° to 100°C; glass body 13 mm diameter x 138 mm long; lead length approximately 39" long. Semi-Micro Type Combination (4136N71) Ideal for routine and high temperature pH measurement for small samples Range 0-14 pH at temperatures from 0° to 100°C Applications: general pH, tris buffers and non-aqueous solutions. AgCl sealed by ion exchange barrier; 238 x 6.3 mm. Rugged Bulb Type Combination (4136N86) Similar to 4136L16 except rugged bulb Applications: general pH and high corrosive acid-bases. Range pH 0-14 at temperatures 0° to 100°C. AgCl Spear-Tip Type Combination (4136S41) Features rugged glass bulb specially formed to enable penetration of meat, cheese, soils and other materials Range pH 0-14, at temperatures from 0° to 100°C. Non-replaceable junction. Combination with ATC (4136S51) General purpose plastic electrode combines pH, reference and temperature. A rugged bulb, detachable bulb protector and replaceable junction (4136L60) provide for long life. High Performance Combination (4136S56) Refillable with 3-molar KCl TRIS compatible Non-replaceable ceramic junction High performance electrode combines innovative design and new pH glass for increased sensivity. 3-in-1 Gel Filled Combination (4136S61) Designed for durability and ease of maintenance Tris compatible Applications: general pH measurement with automatic temperature compensation Tris buffers pH range 0-14, at temperatures from 0° to 80°C. Gel Spear Tip Combination (4136S62) Require less maintenance than refillable electrodes Applications: sampling meats and cheese pH range 0-14, at temperatures from 0° to 80°C. Fast-Flow Combination (4136S67) pH range 0-14, at temperatures from 0° to 100°C Applications: measuring rapidly clogging samples Circular junction flushes KCl solution through the junction or into the sample. General Purpose Gel Combination (4136S69) Less maintenance than refillables pH range 0-14, at temperatures from 0° to 80°C Metallic Type (4136T21) AgCl internal reference is sealed by an ion exchange barrier eliminating heavy metal contamination of samples Replaceable junction pH range 0-14 at temperatures of 0° to 100°C Redox combination electrode is made with high purity, metallic-sensing elements for stable, repeatable oxidation/ reduction measurements. Semi-Micro Gel Combination (4136T24) Require less maintenance than refillable electrodes pH range 0-14, at temperatures from 0° to 80°C Sample depth: 3/8" min. Applications: Measuring samples in culture tubes
UOM : EA


Add to Quote
DISCONTINUED Use 75870-650

DISCONTINUED Use 75870-650

Item #: VAN/11278-220
Supplier #: 11278-220

(( DISCONTINUED -DG115-SC Combination pH Electrode Glass. Mettler Toledo 89806)). Replaced by the DGi115-SC, MET/51109504.
UOM : EA


Add to Quote
  • « PREV
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • NEXT »

Don't see what you need or would like to request a quotation?

Click here to let us know and we'll help you find what you're looking for!