Viscometer
Viewing Page 1 of 1
(9 results)
TUBE VISCOMETER 300MM CS/1
Item #:
KIM/46460-300
Supplier #: 46460-300
Supplier #: 46460-300
KIMAX Cannon-Fenske Viscometer Tube Serialized. Uncalibrated. For obtaining kinematic viscosities of transparent liquids ASTM Method of Test D445 . Viscosity ranges for an efflux time greater than 200 seconds. ASTM size 300. Kinematic viscosity range 50-250mm/second. Constant 0.25. Exact Match 52946-683
Viscometer Tube Saybolt Brass
Item #:
KOE/K22009
Supplier #: K22009
Supplier #: K22009
Tube, Saybolt Viscometer; Koehler Instrument; Brass made; Meets ASTM requirements; Mount vertically in Saybolt Viscometer Baths and accommodate stainless steel orifices interchangeably; With mounting hardware; 1/EA Exact Match 22280284 89003-566
Marsh funnel Viscometer
Item #:
OFI/110-10
Supplier #: 110-10
Supplier #: 110-10
Viscosity and gel strengths are measurements that relate to the flow properties of fluids. The Marsh Funnel Viscometer has been used for many years to obtain an indication of the relative viscosity of drilling fluids (known as Funnel Viscosity). It is calibrated to outflow one quart (946 mL) of fresh water at a temperature of 70 ± 5°F (21 ± 3°C) in 26 ± 0.5 seconds. The OFITE Marsh Funnel Viscometer is molded from a tough, durable plastic that resists breaking or cracking. A brass orifice assures consistency in all readings.
Size: 6.5" × 6.25" × 14.5" (17 × 16 × 37 cm)
Weight: 12 oz (340.2 g)
Saybolt Viscometer +66-80F
Item #:
TMC/ACC017F
Supplier #: ACC017F
Supplier #: ACC017F
Thermometer ASTM thermometer 17F 66 to 80F Saybolt viscosity divisions 0.2F immersion total length 275mm mercury Exact Match 10747-002
Cannon CMVC Series Viscometers Size 11
Item #:
TMS/9724H71
Supplier #: 9724H71
Supplier #: 9724H71
CANNON INSTRUMENT
Mfg Item # : 9724-H71
Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two bulbs are incorporated to extend viscosity range of viscometer. Calibrated with precision of ±0.5%. Minimum sample volume: 6 mL . Requires liquid bath depth of 180 mm (7.1”). Pressure regulator and vacuum manifold for use with these viscometers are listed separately under 9726T20 and V10. For suitable baths, see 9726A20, etc. Includes certificate of calibration and instruction sheet. Individually boxed. Size and serial number are printed on outside of box. Holder is not supplied, see Thomas number 9726N15.
Mfg Item # : 9724-H71
Calibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two bulbs are incorporated to extend viscosity range of viscometer. Calibrated with precision of ±0.5%. Minimum sample volume: 6 mL . Requires liquid bath depth of 180 mm (7.1”). Pressure regulator and vacuum manifold for use with these viscometers are listed separately under 9726T20 and V10. For suitable baths, see 9726A20, etc. Includes certificate of calibration and instruction sheet. Individually boxed. Size and serial number are printed on outside of box. Holder is not supplied, see Thomas number 9726N15.
Viscometer Canon-Fensk Rout 100
Item #:
VAN/47734-934
Supplier #: 47734-934
Supplier #: 47734-934
CANNON INSTRUMENT CO 9721-B59
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 100. Approximate constant: 0.015. Kinematic Viscosity Range: 3 to 15 centistokes. For measuring kinematic viscosity of petroleum products. Minimum sample volume: 7mL. Require liquid bath depth of 203mm. Exact Match: 47734-934
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 100. Approximate constant: 0.015. Kinematic Viscosity Range: 3 to 15 centistokes. For measuring kinematic viscosity of petroleum products. Minimum sample volume: 7mL. Require liquid bath depth of 203mm. Exact Match: 47734-934
Viscometers Routine Calibrated 0.015 c
Item #:
VAN/52946-781
Supplier #: 52946-781
Supplier #: 52946-781
Q GLASS II LLC
Mfg Item # : RT-100
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 100. Nominal constant: 0.015. Range: 3 to 15 centistokes. Viscosities measured with precision of -¦0.2%. Approximately 7mL sample necessary. Specs conform to ASTM Standard D-446. Supplied with certificate.
Exact Match: 52946-781
Mfg Item # : RT-100
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 100. Nominal constant: 0.015. Range: 3 to 15 centistokes. Viscosities measured with precision of -¦0.2%. Approximately 7mL sample necessary. Specs conform to ASTM Standard D-446. Supplied with certificate.
Exact Match: 52946-781
Viscometer 0.035c 7–35 centistokes
Item #:
VAN/52946-783
Supplier #: 52946-783
Supplier #: 52946-783
Q GLASS II LLC
Mfg Item # : RT-150
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 150. Nominal constant: 0.035. Range: 7 to 35 centistokes. Viscosities measured with precision of -¦0.2%. Approximately 7mL sample necessary. Specs conform to ASTM Standard D-446. Supplied with certificate.
Exact Match: 52946-783
Mfg Item # : RT-150
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 150. Nominal constant: 0.035. Range: 7 to 35 centistokes. Viscosities measured with precision of -¦0.2%. Approximately 7mL sample necessary. Specs conform to ASTM Standard D-446. Supplied with certificate.
Exact Match: 52946-783
Viscometers Routine Calibrated ASTM 200
Item #:
VAN/52946-785
Supplier #: 52946-785
Supplier #: 52946-785
Q GLASS II LLC
Mfg Item # : RT-200
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 200. Nominal constant: 0.01. Range: 20 to 100 centistokes. Viscosities measured with precision of -¦0.2%. Approximately 7mL sample necessary. Specs conform to ASTM Standard D-446. Supplied with certificate.
Exact Match: 52946-785
Mfg Item # : RT-200
Cannon-Fenske Routine Viscometer, Calibrated ASTM size: 200. Nominal constant: 0.01. Range: 20 to 100 centistokes. Viscosities measured with precision of -¦0.2%. Approximately 7mL sample necessary. Specs conform to ASTM Standard D-446. Supplied with certificate.
Exact Match: 52946-785